Skip to content
3D Print Troubleshooting, Calibration & Parts

Prusa Error 13201: Preheat Error on the Heatbed

Affiliate disclosure

LayerWalker is a participant in the Amazon Services LLC Associates Program. We may earn a commission when you buy through links on our site, at no extra cost to you.

Prusa Error 13201 — PREHEAT ERROR — heatbed did not reach temperature
Short answer

Prusa error 13201 is a preheat failure on the heatbed: the bed did not reach its target temperature within the time the firmware allows. Prusa’s own text says to check the heatbed heater and thermistor wiring, and that is the right order — reseat the bed connector first, inspect the cable where it flexes, and only then suspect the heating element itself.

The same fault carries a different number on every Prusa model, because the first two digits identify the printer rather than the problem. On a MINI it is 12201, on an MK4 13201, on a CORE One 31201, on an XL-family machine 17201, and on an MK3.5 23201. The cause and the fix are identical.

Where to buy

3
-16%
AstroAI Digital Multimeter Tester 2000 Counts with DC AC Voltmeter and Ohm Volt Amp Meter; Measures Voltage, Current, Resistance, Continuity and Diode, Blue
Limited Time

AstroAI Digital Multimeter Tester 2000 Counts with DC AC Voltmeter and Ohm Volt Amp Meter; Measures Voltage, Current, Resistance, Continuity and Diode, Blue

AstroAI
In Stock
9.7 /10
ACMS Score
ACMS Score is calculated based on product ratings, reviews, and sales performance to help you make informed purchasing decisions.
Updated: Sep 15, 2026
Last update on Sep 15, 2026 / Affiliate links / Images, Product Titles, and Product Highlights from Amazon Creators API.
$18.99 Save $3.00
$15.99

What the printer is actually measuring

The firmware turns the bed heater on and watches the thermistor for a rise. If the temperature does not climb at the expected rate, it stops rather than keep driving a heater it cannot verify. So a 13201 does not mean the bed is broken — it means the printer could not confirm it was working.

Relative likelihood of each cause. Four of the five cost nothing to rule out, so check in this order.
Relative likelihood of each cause. Four of the five cost nothing to rule out, so check in this order.

Check in this order

  1. The heatbed connector. Power down, unplug, look for discolouration, browning or a loose crimp, then reseat it firmly. This is the single commonest cause.
  2. The thermistor wiring. Follow the cable through the drag chain. A broken core inside intact insulation is invisible until you flex it by hand.
  3. Room temperature. Below roughly 15 °C a large bed genuinely can miss the timeout on a cold start. Warm the room and retry before buying anything.
  4. The heater element. With the printer off, measure resistance across the bed heater terminals. Open circuit means the element has failed.
  5. The power supply. Last, not first. A weak PSU usually trips other faults before this one.

If it only happens at high bed temperatures

A bed that reaches 60 °C but errors on the way to 100 °C points at a supply or connector that cannot sustain the current, not at the sensor. That pattern is worth noting when you describe the fault. For what each material actually needs, see bed temperature by material.

Related codes worth not confusing

13202 is the same failure on the print head rather than the bed. 13205 is the bed thermistor reading above its range, which is a different wiring fault. And if the bed heats but the first layer still fails, that is a first-layer problem, not a heater one.

Three neighbouring bed faults worth telling apart: 13207 MINTEMP is an open circuit, 13205 MAXTEMP a short, and this one a heater that never reached target.

Prusa Error 13201 FAQ

Can I keep printing with error 13201?

No. The printer stops because it cannot verify the heater is behaving. Bypassing a heater check is how fires start, and Prusa deliberately does not offer an override.

Is 13201 the same on every Prusa?

Yes, apart from the number. 12201 on MINI, 13201 on MK4, 31201 on CORE One, 17211-series on XL and 23201 on MK3.5 all mean the heatbed failed to preheat.

Does a cold room really cause this?

It can, on a large bed with a cold start below about 15 °C. It is worth ruling out first because it costs nothing, though it is less common than a wiring fault.

Do I need to replace the whole heatbed?

Rarely. Connectors and cabling account for most cases. Only replace the bed after measuring the heater and confirming it is open circuit.